A train-sized tunnel is now carrying electricity under South London

https://www.ianvisits.co.uk/articles/a-train-sized-tunnel-is-now-carrying-electricity-under-south...
33•zeristor•2h ago•30 comments

CSS Grid Lanes

https://webkit.org/blog/17660/introducing-css-grid-lanes/
529•frizlab•12h ago•150 comments

A terminal emulator that runs in your terminal. Powered by Turbo Vision

https://github.com/magiblot/tvterm
38•mariuz•2d ago•4 comments

Mistral OCR 3

https://mistral.ai/news/mistral-ocr-3
541•pember•1d ago•100 comments

What Does a Database for SSDs Look Like?

https://brooker.co.za/blog/2025/12/15/database-for-ssd.html
4•charleshn•42m ago•2 comments

Airbus to migrate critical apps to a sovereign Euro cloud

https://www.theregister.com/2025/12/19/airbus_sovereign_cloud/
101•saubeidl•2h ago•39 comments

Skills Officially Comes to Codex

https://developers.openai.com/codex/skills/
17•rochansinha•2h ago•2 comments

Contrails Map

https://map.contrails.org/
35•schaum•3h ago•13 comments

Garage – An S3 object store so reliable you can run it outside datacenters

https://garagehq.deuxfleurs.fr/
581•ibobev•19h ago•126 comments

TP-Link Tapo C200: Hardcoded Keys, Buffer Overflows and Privacy

https://www.evilsocket.net/2025/12/18/TP-Link-Tapo-C200-Hardcoded-Keys-Buffer-Overflows-and-Priva...
288•sibellavia•16h ago•86 comments

Fuzix on a Raspberry Pi Pico

https://ewpratten.com/blog/fuzix-pi-pico
61•ewpratten•5d ago•5 comments

Carolina Cloud – One third the cost of AWS for data science workloads

https://carolinacloud.io/
105•bojangleslover•5d ago•51 comments

Feast Your Eyes on Japan's Fake Food

https://www.newyorker.com/culture/annals-of-gastronomy/feast-your-eyes-on-japans-fake-food
17•Kaibeezy•4d ago•6 comments

LLM Year in Review

https://karpathy.bearblog.dev/year-in-review-2025/
223•swyx•14h ago•60 comments

Privacy doesn't mean anything anymore, anonymity does

https://servury.com/blog/privacy-is-marketing-anonymity-is-architecture/
92•ybceo•4h ago•74 comments

8-bit Boléro

https://linusakesson.net/music/bolero/index.php
258•Aissen•23h ago•37 comments

Graphite is joining Cursor

https://cursor.com/blog/graphite
229•fosterfriends•18h ago•233 comments

New Quantum Antenna Reveals a Hidden Terahertz World

https://www.sciencedaily.com/releases/2025/12/251213032617.htm
5•aacker•4d ago•0 comments

A better zip bomb (2019)

https://www.bamsoftware.com/hacks/zipbomb/
139•kekqqq•13h ago•51 comments

Reflections on AI at the End of 2025

https://antirez.com/news/157
47•danielfalbo•1h ago•45 comments

Brown/MIT shooting suspect found dead, officials say

https://www.washingtonpost.com/nation/2025/12/18/brown-university-shooting-person-of-interest/
153•anigbrowl•1d ago•187 comments

Sharp: High performance Node.js image processing/optimization

https://github.com/lovell/sharp
9•nateb2022•3d ago•1 comments

Build Your Own React

https://pomb.us/build-your-own-react/
116•howToTestFE•10h ago•7 comments

Gh-actions-lockfile: generate and verify lockfiles for GitHub Actions

https://gh-actions-lockfile.net
36•gjtorikian•3d ago•20 comments

The Deviancy Signal: Having "Nothing to Hide" Is a Threat to Us All

https://thompson2026.com/blog/deviancy-signal/
19•NickForLiberty•5h ago•11 comments

Rust's Block Pattern

https://notgull.net/block-pattern/
182•zdw•1d ago•93 comments

Show HN: TinyPDF – 3kb pdf library (70x smaller than jsPDF)

https://github.com/Lulzx/tinypdf
185•lulzx•1d ago•23 comments

Qwen-Image-Layered: transparency and layer aware open diffusion model

https://huggingface.co/papers/2512.15603
108•dvrp•1d ago•18 comments
Open in hackernews

A train-sized tunnel is now carrying electricity under South London

https://www.ianvisits.co.uk/articles/a-train-sized-tunnel-is-now-carrying-electricity-under-south-london-86221/
33•zeristor•2h ago

Comments

zeristor•2h ago
Impressive piece of work, first time I’ve heard of this.

I had heard that tunnels were a good first step for rolling out super conducting cables, but that doesn’t seem to be a thing.

Superconducting cables have progressed a lot. I’m assuming that setting up a cryogenic system to keep cables cool enough, in a confined space wasn’t thought to be worth it.

The tunnels look tight enough, and boiling liquid nitrogen from a leak could cause asphyxiation I imagine.

lukan•1h ago
"I had heard that tunnels were a good first step for rolling out super conducting cables, but that doesn’t seem to be a thing."

Yeah tunnels underground would be better for superconducting cables, but it is indeed not really a thing as the cooling and installing and maintainance would be waaaay more expensive, than just using higher voltage. Or if one really cares about the loss, use direct current - but we are talking aber very small distances here.

If superconducting would be easy, we likely just would have fusion plants everywhere with no need for transporting electricity long distances.

mr_toad•1h ago
The tunnels are just for ease of maintenance.

https://en.wikipedia.org/wiki/London_Power_Tunnels

locknitpicker•1h ago
> The tunnels are just for ease of maintenance.

The fact that the tunnels are 50 meter underground leads me to wonder if their main requirement comes from national security needs.

defrost•56m ago
London underground is prime real estate - to find a level and avoid

* the recent new massive and extensive sewer tunnels,

* the secret basement extensions of the ultra rich, multi story archival storage, vaults, etc,

* the new underground tunnels (rail / subway for US readers),

* old roman and other buried but still 'conserved' architecture,

* crypts, graves, plague pits,

* WWII UXB's etc. etc

is a hell of a 3D needle to thread - there's > 2,000 years of urban layering in that small area.

ant6n•56m ago
There’s Probably simply too much city in the way on higher levels.

If you wanna knock out the grid, hit the substations and power plants.

zeristor•1h ago
From Gridlock to Grid Power: The Promise of Superconducting Cables

https://ee.eng.cam.ac.uk/index.php/2025/09/22/from-gridlock-...

An interesting article, I’ll download the IoP report and maybe read it.

But it talks about doing the hard work to improve the Technological Readiness Level from 7 to 9. Although these cables need rare earths so might be problematic.

luma•1h ago
Anyone have any idea why the cables are arranged like this? https://8400e186.delivery.rocketcdn.me/articles/wp-content/u...

What's the zig-zag pattern for, seems like a fair bit of extra conductor.

probablypower•1h ago
First guess (may be wrong) is to manage thermal expansion/contraction constantly on a micro-scale.
nraynaud•1h ago
I would also add that there some slack for repairs.
jo909•1h ago
This view is just very extreme, it is much less zig zag. It is just mounted to the wall at the high points and slack in between. Certainly there is also a reason for the exact amount of slack like thermal expansion.

https://cdn.ca.emap.com/wp-content/uploads/sites/9/2018/04/l...

defrost•1h ago
There are three reasons:

* Cable thermal expansion under current load: https://www.ahelek.com/news/cable-thermal-expansion-and-its-...

* The amount pictured is in excess of that required for thermal expansion. The excess is to have some spare length in case of modifications. For example if you have to replace the transformer and the terminals are not in the same location. You cannot extend a massive cable like that easily or without degrading its specs.

* The sine wave pattern makes it into AC of course (/s)

locknitpicker•1h ago
> Anyone have any idea why the cables are arranged like this?

I think that's just cables sagging, which is a requirement to accommodate thermal and seismic displacements.

Reason077•31m ago
Is that a tandem bicycle? Cute.
jimnotgym•1h ago
So Everywhere else in Britain it is 'too expensive' to put cables underground. Just goes to show how London centric this country is.
jasoncartwright•1h ago
Sounds like you are trying to compare the many hundreds of miles (thousands?) of transmission cables needed to cope with the massive geographic change of generation sources to this ~20mi cable system.

There are many examples of how the UK is London-centric. This isn't one of them.

VBprogrammer•1h ago
It sounds like sour grapes. London contributes nearly a third of the UKs tax income. It has a higher population than the whole of Scotland.

Not to mention that over ground wires are manifestly better in every dimension except for aesthetics.

This is a great example:

https://youtu.be/z-wQnWUhX5Y?si=qdqrpJ-zS7lh2J8Z

ra•1h ago
I know what you're saying, but maybe there is a tipping point when the economics is worth it.

Cool to see cycling down there - much safer than on the roads above.

nkmnz•1h ago
What are the costs of an underground cable in the cities you’re considering, expressed as:

1. Cost per kWh transmitted?

2. Cost per person served?

3. Cost per pound of GDP generated?

Please provide this for London and the other locations you have in mind.

docflabby•1h ago
London and the south east is the UK in economic terms. Its the only those 2 regions which are net contributor to taxes

https://www.ons.gov.uk/economy/governmentpublicsectorandtaxe...

zeristor•1h ago
Manchester is burgeoning, still someways behind London.

It’d be super, smashing, great! for the cities to be far better connected together across the Pennines.

walthamstow•44m ago
You're lucky to have us mate. London is the only thing going for this country. We should be betting /more/ on London.
immibis•42m ago
On the flip side, that's mostly because London takes all their wealth and crowds out wealth generation
walthamstow•31m ago
People move to where the jobs are. That's how most English towns came to exist in the first place in industrial revolution.

We're ~30 years into a new information/digital revolution and London is a world centre of it. There's plenty of wealth generation happening. People are welcome to sit and wait for it to come to them if they want.

KaiserPro•27m ago
Yes.

And I wish people would understand how costs work.

Pylons need space right, they also need maintenance corridors and access. Every ~360m you need a space to put a pylon[1]. Can you imagine the cost of buying 400m2 every 360 in zone 1?

what about the scaffolding when you need to re-string the cables? can you imagine how expensive that would be? what about if a lorry smacks into it? Its just not practical.

I grew up in norfolk, next to a bunch of HV pylons. No-one commented on them, because they were always there. THey are going to put some more in, and suddenly "its a blot on the land scape" and its "ecological damaging" Then its proposed that the cables are buried. apparently a 200 meter clearing 30km long is more ecologically friendly than pylons ever n hundred meters.

but thats an aside.

[1]https://www.quora.com/What-is-the-distance-between-electrici...

nopurpose•1h ago
Cables on overhead high voltage lines are mounted using stacks of ceramic insulators, but here they seemingly just sleeved in some protection and hang on a tunnel wall. Why is that?
jo909•1h ago
Overhead high voltage conductors are not insulated with a coating, probably for many reasons but certainly for cost and heat dissipation.

That means the path through the air to some conducting materials needs a certain distance, and that even when wet or iced over or whatever can happen up there.

VBprogrammer•1h ago
Overhead conductors use air as the insulator. Underground cables use an insulating jacket. In the past it was really difficult to build cables with voltage ranges in the 10s of thousands of volts without additional complexity like a dielectric oil being pumped through the cable. I think modern dielectrics are significantly better though.
KaiserPro•43m ago
Cost, mainly

The cost of oil insulated cables that can do 132kv is about £900 a meter. Whilst there are HV cables that exist on the outskirts of london, they are much rarer in zones 1-3.

I assume that the cost of pylons with raw cables is much much cheaper. The problem is planning permissions, physical clearance. planning permission and now one wants to live near HV cables (that they know of. There are a bunch of 33kv cables buried outside posh people's houses in zone 5, and a bunch in canals.)

metalman•1h ago
essentialy no choice in putting infrastructure underground as the cost's and delays in putting a power corridor right of way through is unthinkable, they will almost certainly be useing old established locations for transformer substations that have the required set backs and other services, which must from time to time, come to the frenzied attention of developers, agast ,that they cant relieve someone of this "vacant" land